Cookies must be enabled the site to operate property!

Flook blood pressure checker checker tester fluke instruction manual NIBP medical hospital biological information simulator maintenance clinical engineering ME maintenance inspection
Auction ends 2 days
Bidsno
Current price ¥180,000 $1,235
Start price ¥180,000 $1,235
Buy-now ¥181,000 $1,242
Consumption tax 10% not included
Seller kumagawa1983 +223
Condition Used
Start time 2024-04-29T21:53:20+09:00
End time 2024-05-02T21:53:20+09:00
Auto-prolongation Turned on
Lot number j1086451774
Seller position Okinawa Prefecture

Cost estimation

Lot
Currency
Price
Tax
Weight

kg

Shipping
Method
From Japan
To loading...

Fees & Total
Tax

System fee

Bank transfer

Total

Thank you for seeing the product.
Please be sure to check the following points and the contents described in the store information before bidding.
[Sales permit]
Permit number South 0500001886
Advanced Advanced Medical Equipment Sales Business Permit
[Product Description]
Brand, Maker: Fluke Flook Biomedical
Model number: CUFF LINK
Equipment type: Blood pressure monitorcheckerBlood pressure tester
Production year: Unknown
Use applications
Used to evaluate the measurement accuracy of the blood pressure gauge of the biological information monitor. In addition, it is used for inspection and maintenance of blood pressure gauge..
Compare the blood pressure value set in the cuff link and the measured measurement value actually measured to confirm whether it is within the error..
Also,By comparing the pressure gauge in the blood pressure gauge and the pressure gauge in CUFFLINK, it is used to check the blood pressure transduca..
In addition, it is possible to perform a leak test, etc..
Evaluation method of setting method and blood pressure measurement accuracy (Photo 4)
1. Connect the T -shaped connector tube adapter for various accessories to CUFFLINK CUFF Connect.
2. A biological information monitor that wants to check the blood pressure functionConnect a hose for blood pressure measurement to the T -shaped connector tube adapter.
3. Wrap the cuff you want to check the blood pressure function to the phantom arm and connect the tip to the adapter of the T -shaped connector tube..
4. Turn on the Cuff Link.
5. Select an adult mode or newborn mode and press the ENT key.
6. Select the maximum blood pressure and the minimum blood pressure configuration and press the ENT key..
7. Press the blood pressure measurement button on the biological information monitor.
8. Compare the blood pressure measurement value of the biological information monitor with the blood pressure setting value of CUFFLINK to confirm whether it is within the error..
Please refer to the instruction manual for details.
Available biological information monitor manufacturers
Since the connection connector of each manufacturer is provided in the set contents,
It can be used for biological information monitors such as Nippon Kogeni, Fukuda Electronics, Omron, Colin, Philips, and blood pressure measuring instruments..
【set content】
1. Tester body (Photo 1)
2. Japan Light Electric Body Information Monitor Adapter (Photo 5)
3. Two types of adapters for Fukuda Electronics, Colin Omron, Biological Information Monitor (Photo 5)
4. Philips biological information monitor adapter (Photo 5)
5. Various spare connectors
6. power cable
7. For phantom arm adults
8. Phantom arm for infants and newborns
9. Japanese instruction manual
Ten. Back for accessories
11. aluminum case
* The blood pressure monitor and the biometric information monitor in the photo and their accessories are not included in the set contents.
【Checklist】
1. When the power switch of the tester is turned on, the power is not availableconfirmed.(photo1)
2. After the setting was completed,When you set a blood pressure value to cufflink and press the start button on the biometric information monitor, press the start button,
To cufflinkI confirmed that the mock waveform is output.(Photo 5, Photo 6)
3. When the CUFFLINK setting value is maximum blood pressure 100 and the minimum blood pressure 65, the actual measurement value is 101, the minimum blood pressure 63
When the CUFFLINK setting value is 120 and the lowest blood pressure is 80, the actual measurement value is 117, the minimum blood pressure 77
So, it was confirmed that the error between the set value and the measured value is within ± 10 (Photo 5, Photo 6).
[Notes on products]
1. In the instruction manual, the original is scanned by a multifunction device, and the copy is filed.
2. Please note that the bio -information monitor shown in the photo, accessories such as hoses for blood pressure measurement, cuff, etc. are not included in the set contents.
3. Since this product is a device that checks the measurement accuracy of the blood pressure gauge gauge gauge gauge, such as the biometric information monitor used in the hospital, this product is used.
Please note that it cannot be used for home blood pressure gauge.
[Notes on transactions]
1. Regarding how to deliver, shipping, bundling
Yamato Transport Kayu Pack, 120cm size is planned. The shipping fee is 4000 yen nationwide.
2. Regarding receipt
You can issue a receipt. If necessary, please contact us for the address and the proviso.
3. About payment
The payment amount is a separate consumption tax on the product price, and the amount will be added.
The payment deadline is within 4 days after a successful bid. If payment is difficult within the deadline, please contact us by the transaction message.
If there is no payment and there is no payment, if the 5th day after the successful bid date and time and the fifth day, we will cancel the successful bid due to the highest bidder convenience.
In that case, the successful bidder will automatically give a bad evaluation. Please note.
4. About returned goods
(A.) Since we handle second -hand goods, we do not accept returns and exchanges for customers' convenience products..
(B.) However, we will accept returns and exchanges in the following two cases..
1. When the confirmation items described in the product description field and the contents of the posted photo are significantly different from the current status of the arrived.
2. If the product is damaged at the time of mailing
Corresponding procedure
(1.) If you would like to return or exchange for 1 and 2 reasons above, please contact us by e -mail or telephone..
* If you wish to return or exchange, please contact us within 3 days from the date and time of receiving the product from the courier.
Please note that we cannot accept returns and exchanges after the deadline
(2.) We will continue to inform you of the matters you want to ask for confirmation from our company..
Sorry to trouble you, but please check the successful bidder and reply.
We may ask you to send a photo additionally. Please note.
We will determine whether it corresponds to 1 and 2 to be returned or exchanged from the response, and will contact you.
* If there is no reply to the confirmation, it cannot be determined whether it corresponds to 1 and 2.
If there is no reply for 4 days or more from our contact, we will cancel the response.
In this case, please note that we cannot accept returned or exchanged for any reason
(3.) If the return is returned, we will refund the specified account regardless of the payment method..
If you wish to replace it, it is limited to the same type of product stock.
(4.) We will bear the shipping cost for returning and resending the product only in the case of 1 and 2..
(C.) Thank you for checking the current status of the product and consultation on the future response..
In this case, we cannot receive the product.
(D.) If it is judged that it is a mailing accident, we will contact the highest bidder and contact the post office of the shipment source for mail accident..
loading...
TimeUserPrice
No bids
loading...

No questions yet. To ask a question you need to be authorized.
Please, sign in or register. Refresh the page once done.